Baseline
Electrical Performance Metrics Of A Fabricated 1.9 KVA Fuel-Less
Electromechanical Generator For Irrigation Technology Instruction In National
Diploma Awarding Institutions In Taraba State, Nigeria
Tikon,
Simon Danladi1; Melaiye, Rufus Oni (Ph.D) 2; Anierobi,
Jennifer Onyekachi3
&
NZAJE, Isaac Peter4
1Department of Agricultural
Education,
College
of Education, Zing, Taraba State, Nigeria
(danladitikonsimon@gmail.com)
2,3 Department of Vocational and
Technology Education,
Taraba
State University, Jalingo, Taraba State, Nigeria
4Department of Technical Education,
College
of Education, Zing, Taraba State, Nigeria
ABSTRACT
This study examined the baseline
electrical performance metrics generated by a fabricated 1.9 KVA closed-loop
fuel-less electromechanical generator prototype under controlled laboratory
bench-testing conditions. The prototype was designed as an alternative
instructional resource for teaching practical irrigation technology in National
Diploma (ND) awarding institutions in Taraba State, Nigeria, where chronic grid
power failures and prohibitive fossil fuel costs cripple workshop-based
training delivery. Guided by one research question this study adopted an
integrated engineering Research and Development (R&D) design combined with
Experimental Design protocols. The prototype, comprising a 12V deep-cycle
battery bank, a 3HP DC motor, a 1.9 KVA synchronous alternator, and a
solid-state diode-rectifier feedback charging circuit, was subjected to incremental
resistive load trials ranging from 100W to 500W. Terminal voltage, current
draw, and derived active power were logged using digital voltmeters, ammeters,
and watt-meters. Energy transformation efficiency was computed using η =
(P_output / P_input) × 100%. Inferential hypothesis testing was conducted using
a one-sample t-test at α = 0.05 significance level. The results revealed
that the prototype maintained excellent voltage regulation, recording only a
4.5% voltage drop from 220V to 210V as the load scaled from 100W to 500W. The
current draw increased linearly from 0.45A to 2.30A, and the derived active
power output reached a peak of 483.0W under the maximum test load. The system
attained peak energy transformation efficiency of 74.3% at the 500W operating
point. One-sample t-test analysis returned statistically significant values
across all evaluated electrical output parameters (p < 0.05), leading to the
rejection of the null hypothesis H₀₂. These findings confirm that
the fabricated prototype produces statistically significant and structurally
stable electrical output parameters suitable for powering small-scale
agricultural irrigation equipment within National Diploma technical workshops.
Keywords: Baseline Electrical Performance, Voltage Regulation, Irrigation Technology