International Journal of Innovative Scientific & Engineering

Technologies Research 14(4):26-34, Oct,-Dec., 2026

 © SEAHI PUBLICATIONS, 2026    www.seahipublications.org    ISSN: 2360-896X

 

 

DOI:10.5281/zenodo.23457827

Baseline Electrical Performance Metrics Of A Fabricated 1.9 KVA Fuel-Less Electromechanical Generator For Irrigation Technology Instruction In National Diploma Awarding Institutions In Taraba State, Nigeria

 

Tikon, Simon Danladi1; Melaiye, Rufus Oni (Ph.D) 2; Anierobi, Jennifer Onyekachi3

& NZAJE, Isaac Peter4

 

1Department of Agricultural Education,

College of Education, Zing, Taraba State, Nigeria
(danladitikonsimon@gmail.com)

 

2,3 Department of Vocational and Technology Education,

Taraba State University, Jalingo, Taraba State, Nigeria


4Department of Technical Education,

College of Education, Zing, Taraba State, Nigeria

 

ABSTRACT

This study examined the baseline electrical performance metrics generated by a fabricated 1.9 KVA closed-loop fuel-less electromechanical generator prototype under controlled laboratory bench-testing conditions. The prototype was designed as an alternative instructional resource for teaching practical irrigation technology in National Diploma (ND) awarding institutions in Taraba State, Nigeria, where chronic grid power failures and prohibitive fossil fuel costs cripple workshop-based training delivery. Guided by one research question this study adopted an integrated engineering Research and Development (R&D) design combined with Experimental Design protocols. The prototype, comprising a 12V deep-cycle battery bank, a 3HP DC motor, a 1.9 KVA synchronous alternator, and a solid-state diode-rectifier feedback charging circuit, was subjected to incremental resistive load trials ranging from 100W to 500W. Terminal voltage, current draw, and derived active power were logged using digital voltmeters, ammeters, and watt-meters. Energy transformation efficiency was computed using η = (P_output / P_input) × 100%. Inferential hypothesis testing was conducted using a one-sample t-test at α = 0.05 significance level. The results revealed that the prototype maintained excellent voltage regulation, recording only a 4.5% voltage drop from 220V to 210V as the load scaled from 100W to 500W. The current draw increased linearly from 0.45A to 2.30A, and the derived active power output reached a peak of 483.0W under the maximum test load. The system attained peak energy transformation efficiency of 74.3% at the 500W operating point. One-sample t-test analysis returned statistically significant values across all evaluated electrical output parameters (p < 0.05), leading to the rejection of the null hypothesis H₀₂. These findings confirm that the fabricated prototype produces statistically significant and structurally stable electrical output parameters suitable for powering small-scale agricultural irrigation equipment within National Diploma technical workshops.

Keywords: Baseline Electrical Performance, Voltage Regulation,  Irrigation Technology